This page gives the technical data of the GDM linear stages. The table lists the electrical and mechanical parameters for the available models.
| Parameter | Unit | Symbol | GDM250XS | GDM350XS | GDM350ES |
| Rated Force | N | Fr | 109 | 191 | 269 |
| Peak Force | N | Fp | 709 | 1242 | 1749 |
| Carriage length | mm | Lt | 305 | 305 | 502 |
| Unit length | mm | Lm | Stroke+305 | Stroke+305 | Stroke+502 |
| Slider diameter | mm | D | 25 | 35 | 35 |
| Pole pitch | mm | 2p | 60 | 60 | 60 |
| Force constant | N/A | Fc | 52 | 73 | 73 |
| Rated current | A | Ia | 2.1 | 2.6 | 3.6 |
| BEMF constant | Vrms/m/s | Ke | 32.35 | 42.4 | 43.6 |
| Phase resistance | ohm | Rph | 10.6 | 7.65 | 5.25 |
| Phase inductance | mH | Lph | 16.5 | 7.5 | 4.9 |
- The rated force (Fr) and peak force (Fp) are the continuous and short-term force. - The unit length depends on the stroke: it is the stroke plus the carriage length. - The pole pitch, force constant, and BEMF constant define the electrical and commutation behaviour. - The phase resistance and phase inductance are the winding parameters for the drive sizing.