This page gives the technical data of the NLi integrated drive linear motors. The table lists the main electrical and mechanical parameters for the available models.
| PARAMETER | UNIT | SYMBOL | NLi080Q | NLi080X | NLi120Q | NLi120X |
| Rated Force | N | Fr | 4.8 | 8,6 | 20.6 | 39,0 |
| Peak Force | N | Fp | 31.2 | 56,2 | 137,3 | 247,1 |
| Pole pitch | mm | pp | 30 | 30 | 60 | 60 |
| Force constant | N/A | Fc | 2 | 2 | 12 | 12 |
| Position repeatability | mm | 0,015 | 0,015 | 0,029 | 0,029 | |
| Slider diameter | mm | D | 8 | 8 | 12 | 12 |
| Slider weight | Kg/m | 0,35 | 0,35 | 0,78 | 0,78 |
For detailed information about motor parameters, please use the Datasheet Engine tool considering the motor code without āiā.
Link: Datasheet Engine
- Rated force (Fr) is the continuous force at the rated duty cycle; Peak force (Fp) is the short-term force. - Pole pitch and force constant determine the commutation and the force per amp. - Position repeatability is the achievable positioning repeatability for the application. - Use the Datasheet Engine tool with the motor code without the āiā to get the detailed datasheet and the force-velocity curves.