Ordering code

This page explains how to build the ordering code of the NL-EB15 safety device. The code selects the model, the beam count, the beam space, the output type, and the sensing distance.

NL-EB15 -10 20 P C C - 2
Model BeamsBeam spaceOutput signalOutput contactScanning method Sensing distance
NL-EB15 series 04,06,08,10.1210,20,40mmP=PNP, N=NPNC=normally closeC=cross scanning, P=parallel scanning 0,5⇒0.1 to 0,5m
2⇒0.1 to 2m
4⇒01, to 4m

Example: NL-EB15-10-20-P-C-C-2

How to build the code

- Model: NL-EB15 series. - Beams: number of beams (04, 06, 08, 10, 12). - Beam space: 10, 20, or 40 mm. - Output signal: P = PNP, N = NPN. - Output contact: C = normally close. - Scanning method: C = cross scanning, P = parallel scanning. - Sensing distance: 0.5, 2, or 4 m.