Table of Contents

Connections

MODBUS RTU only

gdi_integrated_connectors.jpg

LED Indicators

LEDColorDescription / Function
LED 1GreenPower - Pulsing when motor is in no Fault
LED 2RedBlinking when in MODBUS communication with PLC or NiLAB Starter - Fix when the motor is in Fault

Cables

GDI integrated drive motor is equipped with two M12 connectors.
For power connector ⇒ power female DA00022011 flying leads and for signal connector ⇒ signal male DA00012011.

da0012011_image.jpgda00022011_image.jpg
Signal cable DA00012011Power cable DA022022

The signal cable DA00012011 terminates with with D-SUB15 male connector with this pinout:

D-SUB 15
Pinout
SIGNAL DESCRIPTION FUNCTION
1RS485_BModbus B
2RS485_AModbus A
3GNDGround
4NCNot connected
5NCNot connected
6GNDGround
7GNDGround
8DIG_IN_0Digital Input 0 (24V logic)Enable/Homing
9DIG_IN_1Digital Input 1 (24V logic)Motion trigger
10DIG_OUT_0Digital output 0 (24V logic, PNP)Motor running
11DIG_OUT_1Digital output 1 (24V logic, PNP)Motor fault
12DIG_OUT_2Digital output 2 (24V logic, PNP)Programmable

The programmable output have the following options: In Position, Homing in progress, Overtemp fault, sin/cos fault, I2T fault, Master sync, gripper command. This is programmable with NiLAB Starter software.