Fulltext results:
- Glossary
- from slower to faster.\\ **Accuracy: **Difference between expected position and achieved position.\\ **Back... s.\\ **Backlash: **The non-responsive lost motion between a drive screw and its nut that occurs at the poin... tic “detenting” forces created by relative motion between a motor's permanent magnets and its ferrous core ... ght force ripple is present due\\ to the mismatch between the three phase trapezoidal shape and the motor's
- Attraction force @ironcore_motors
- Attraction force ====== ===== Attractive forces between the primary and the secondary part ===== When it... otor has a permanently effective attractive force between the primary and the secondary that results from i... the attractive force must not reduce the air gap between the primary and the secondary. The mechanical des... data”.** ===== Air-gap-related attractive forces between the primary and the secondary ===== The attracti
- Motor components arrangement @ironcore_motors
- espect to place and time, and sufficient rigidity between the motors cannot be ensured. This is frequently ... drive controller. It is possible if the coupling between the motors can be very rigid. {{:ironcore_motors... of the motors within the axis\\ • Position offset between the primary parts <1 mm in feed direction\\ • Position offset between the secondary parts <1 mm in feed direction\\ • S
- uPLC @integrated_drive_motors
- contains the result of the logical AND operation between itself and the y bit of the Pa parameter| |{{:int... contains the result of the logical AND operation between itself and the y bit of the negated Pa parameter|... k contains the result of the logical OR operation between itself and the y bit of the Pa parameter| |{{:int... k contains the result of the logical OR operation between itself and the y bit of the negated Pa parameter|
- Faults Diagnosys and reset @integrated_drive_motors
- he acceleration rate or increase the waiting time between the motion tasks.| |10|0xA|STORE_CONFIG_TO_FLASH_... he acceleration rate or increase the waiting time between the motion tasks. Check the threshold temperature... he acceleration rate or increase the waiting time between the motion tasks. Check the threshold temperature
- Installation procedure @green_drive_iso
- safety distance ! __A minimum distance of 15 cm between the rods or between the rod and any metallic materials around the mouting area must be maintened.__ __Use
- Green Drive in Parallel drive @green_drive_motors
- 61|formula.jpg}}\\ where Fdif is Force difference between the two coils, Fgen is the force generated, Dfid ... recommended that the mounting position difference between the Linear Shaft Motors [Δx= Δx1- Δx2] be less th
- Connection system @integrated_drive_motors
- the termination on the node, please make a jumper between CAN_RES andf CAN_L (Pin 9 and Pin 11) === CONNEC... the termination on the node, please make a jumper between CAN_RES andf CAN_L (Pin 8 and Pin 2) ===== M12 p
- Installation tolerances @ironcore_motors
- the specified performance data,\\ • to a contact between the primary and the secondary and thus to damaged... nd dynamic load of the drive\\ • Attraction force between primary and secondary part\\ Please note that att
- Mounting example @ironcore_motors
- \ Warning: pay attention to the attraction forces between the magnetic way and the linear guides. Bring the... ing: pay attention to leave a minimum gap of 5 cm between the magnetic way and the motor assembly in order
- Installation @mbd_servo_drive
- 1.5% for every 100m.\\ Ensure a level of humidity between 10% and 95%, non-condensing.\\ Make sure that the... ection as robust as possible (large surface area) between the circuit indicated and grounding bar or metal
- Motion modes @nilab_starter
- ). Inside the table the sequence is a closed loop between the first and the last row of the table. In the e... is execeuted from 5 to 9 row. In order to switch between the two table, the input 0 must be low and the in
- Installation @nl7_servo
- please leave at least 10mm installation space in between drivers. If drivers need to be mounted compactly,... in rows and use heat insulation board to separate between rows. Cooling fans are recommended for drivers to
- Wiring Diagram @nl7_servo
- ower supply, especially if power supply is shared between multiple components. Insufficient supply current ... ower supply, especially if power supply is shared between multiple components. Insufficient supply current
- Requirements on the design
- lems. There is no control engineering correlation between the moved slide mass and the motor's mass, as thi