meta data for this page
  •  

Search

You can find the results of your search below.

Fulltext results:

Encoder Calibration @reverso_encoder
36 Hits, Last modified:
====== Encoder Calibration ====== ===== Using Encoder Configurator ===== Before start to use, after the encoder mounting on the machine, two operation are needed... === Dumping of the input signal ==== Using NiLAB Encoder Configuration utility, select the right COM port
Pacdrive 3 - Schneider Electric @reverso_encoder
12 Hits, Last modified:
ine/new_websmart/read_datasheet.php]] {{:reverso_encoder:expert_conf.jpg?nolink&1053x425|expert_conf.jpg}}... he name of Lexium LXM62 Linear Drive) {{:reverso_encoder:store_location.jpg?direct&1773x95|store_location.... ssfully procedure, swtich the power supply of the encoder and the drive off. When the drive is restarted, s... The servo drive must be without error showing the encoder position value without errors. Now select the PS
Mechanical Dimensions @reverso_encoder
11 Hits, Last modified:
====== Mechanical Dimensions ====== {{:reverso_encoder:encoder_view.jpg?direct&1000x520|encoder_view.jpg}} |**Encoder Model** |**La** |**Lt** | |Revenc_736|736|856| |Revenc_660|660|780| La is the Acti
Drive with analog reference @mbd_servo_drive
10 Hits, Last modified:
it is fitted with an output "line driver" 5V type encoder emulation.\\ The resolution of the emulated encoder is the same as the main motor encoder. You can't set an encoder emulation with a variable number of pulses / revolutions. It is possible to find
Encoder @nl_bcj_linear_stage
10 Hits, Last modified:
====== Encoder ====== Standard integrated encoder (magnetic type) with Digital Output ABZ. {{:nl_bcj_linear_stage:encoder_photo.jpg?nolink&315x291|encoder_photo.jpg}} Encoder cable can be 5,8,12 meter.\\ Encoder resolution with
Hiperface communication @reverso_encoder
9 Hits, Last modified:
h Parity Even, 8 Data Bits, 1 Stop bit.\\ Default encoder address is 64dec ⇒ 0x40. CRC type is XOR: [[https... B0 is LSB of actual position (unsigned 32 bit)| |Encoder Reset|0x40 0x53 0x13|No response|–| |Read encoder status|0x40 0x50 0x10|0x40 0x50 B1 B0 CRC|B1 is MSB B0 is LSB of encoder status (see table below for encoder faults)| |Rea
SIN/COS 1Vpp Output Signal @reverso_encoder
9 Hits, Last modified:
mple of SIN/COS Output (Blue and Yellow) with the encoder configured with 16mm of sine period.\\ The signal... fore the conversion and conditioning. {{:reverso_encoder:sin_cos_2.jpg?direct&650x449|sin_cos_2.jpg}} Exa... mple of SIN/COS Output (Blue and Yellow) with the encoder configured with 8mm of sine period.\\ The signal ... fore the conversion and conditioning. {{:reverso_encoder:sin_cos_4_1.jpg?direct&650x394|sin_cos_4_1.jpg}}
Integrated Encoder @green_drive_iso
6 Hits, Last modified:
===== Integrated Encoder ===== ==== SIN/COS 1Vpp (Default) ==== The green drive tubular linear motor is equipped with integrated SIN/COS 1Vpp encoder. The signal output is differential type with a re... SIN-, COS+, COS- that represent the output of the encoder system.\\ The integrated encoder must be powered by +5VDC +/-10%. {{:green_drive_motors:sin_cos_1vpp.jpg?
Integrated Encoder @green_drive_motors
6 Hits, Last modified:
===== Integrated Encoder ===== ==== SIN/COS 1Vpp (Default) ==== the green drive tubular linear motor is equipped with integrated SIN/COS 1Vpp encoder. The signal output is differential type with a re... ,SIN-,COS+, COS- that represent the output of the encoder system.\\ The integrated encoder must be powered by +5VDC +/-10%. {{:green_drive_motors:sin_cos_1vpp.jpg?
Glossary
5 Hits, Last modified:
s per Meter is equal to1 divided by resolution on encoder.\\ **Coefficient** **of** **Kinetic** **Friction*... put to the motor to reach 63.2% of its value.\\ **Encoder**: A position-sensing device that translates mech... per Meter is equal to 1 divided by resolution on encoder divided by 4.\\ **Repeatability**, **Bi**-**direc... The value results from the feedback's precision (encoder, laser, etc.) and the controller's logic multipli
Repeatability @green_drive_motors
5 Hits, Last modified:
e monodirectional repeatability of the integrated encoder mounted on the motor. In general repeatability is... Drive linear motor, equipped with the integrated encoder under test, is connected by a linear joint to a m... . The master motor position is read by an optical encoder (1μm of resolution). The system is controlled by ... ve or miniature linear motors from the integrated encoder signals. ===== Description of measurement =====
Encoder Configurator @reverso_encoder
5 Hits, Last modified:
====== Encoder Configurator ====== Encoder Configurator is a software running on windows for calibration, monitoring and checking of the reverso encoder. The communication from PC and encoder is based on RS485 communication interface using a programming cabl
Reverso Encoder @reverso_encoder
5 Hits, Last modified:
====== Reverso Encoder ====== **RevEnc** is an innovative encoder based on magnetic field detection of a reference magnet. The r... or DSL compatible with Sick protocol. {{:reverso_encoder:revenc.jpg?nolink&596x268|revenc.jpg}} The mount... cting region is not critical, from 5 to 20mm. The encoder is tunable and programmable using PC software. T
Holding brake @nl7_servo
4 Hits, Last modified:
oltage drop. * If the motor is using a magnetic encoder, holding brake wires need to be differentiated be... terminal to prevent interference to the magnetic encoder due to wrong polarity. It might cause alarm, loss in encoder accuracy or abnormal vibration, etc. Motor with optical encoder has no such problem, so holding brake circuit can
Connector pinout @reverso_encoder
4 Hits, Last modified:
ut ====== Connector is M17 - 12 pins {{:reverso_encoder:connector_photo.png?nolink&244x238}} |**PIN N.**... DC|White/Brown|12VDC Output|-| |3|GND|White/Black|Encoder Ground|8| |4|GND|Black|Encoder Ground|7| |1|24VDC|Red|Encoder Power Supply +24VDC|9| *Sin/Cos Period depending on the configuration
Service Bulletin - Integrated Encoder @service_bulletin
4 Hits, Last modified:
Main technical data @epulse50_dc_servodrive
3 Hits, Last modified:
Maintenance @integrated_drive_motors
3 Hits, Last modified:
Integrated Encoder @lma_actuator
3 Hits, Last modified:
NiLAB Starter Software @nilab_starter
3 Hits, Last modified:
Starter Status Area @nilab_starter
3 Hits, Last modified:
Technical Data @reverso_encoder
3 Hits, Last modified:
BISS-C Encoder interface @green_drive_iso
2 Hits, Last modified:
BISS-C Encoder interface @green_drive_motors
2 Hits, Last modified:
Lexium32M Drive @green_drive_motors
2 Hits, Last modified:
Faults Diagnosys and reset @integrated_drive_motors
2 Hits, Last modified:
LM Linear Stage @lm_linear_axes
2 Hits, Last modified:
General Motor Configuration @mbd_servo_drive
2 Hits, Last modified:
MBD 230/400 Servo Drive @mbd_servo_drive
2 Hits, Last modified:
Cable coding system @mbm_motors
2 Hits, Last modified:
NL-BCJ Eco Linear stage @nl_bcj_linear_stage
2 Hits, Last modified:
Encoder cables @nl7_servo
2 Hits, Last modified:
Encoder output port - CN5 @nl7_servo
2 Hits, Last modified:
Kinetix 5700 Rockwell servo drive @reverso_encoder
2 Hits, Last modified:
USB Programming cable @epulse50_dc_servodrive
1 Hits, Last modified:
Epulse 30/50/100 DC Servo drive @epulse50_dc_servodrive
1 Hits, Last modified:
GDi ISO-EtherCAT integrated linear motor @gdi_ethercat
1 Hits, Last modified:
Encoder type @gdm_linear_axes
1 Hits, Last modified:
GDM Tubular Linear Stage @gdm_linear_axes
1 Hits, Last modified:
How to use connectors @green_drive_iso
1 Hits, Last modified:
Siemens Sinamics S120 / G120 @green_drive_iso
1 Hits, Last modified:
Cable coding system @green_drive_motors
1 Hits, Last modified:
How to use connectors @green_drive_motors
1 Hits, Last modified:
Siemens Sinamics S120 / G120 @green_drive_motors
1 Hits, Last modified:
Green Drive in Parallel drive @green_drive_motors
1 Hits, Last modified:
EtherCAT to MODBUS RTU Gateway @gtw_ethercat
1 Hits, Last modified:
Can Open standard SDOs @integrated_drive_motors
1 Hits, Last modified:
MODBUS RTU Communication @integrated_drive_motors
1 Hits, Last modified:
Connectors Pinout @lma_actuator
1 Hits, Last modified:
Nidec M700 Servo Drive @lma_actuator
1 Hits, Last modified:
LMA Linear actuator @lma_actuator
1 Hits, Last modified:
Motor feedback @mbd_servo_drive
1 Hits, Last modified:
Safety @mbd_servo_drive
1 Hits, Last modified:
MBM AC Brushless Servomotors @mbm_motors
1 Hits, Last modified:
Elmo Servo Drive @miniature_motors
1 Hits, Last modified:
GHA Coating @miniature_motors
1 Hits, Last modified:
NL miniature linear motors @miniature_motors
1 Hits, Last modified:
MEQI Ballscrew actuator @motolab_actuator
1 Hits, Last modified:
Expert Mode @nilab_starter
1 Hits, Last modified:
Starter interface windows @nilab_starter
1 Hits, Last modified:
How to save and reload the configuration @nilab_starter
1 Hits, Last modified:
Ordering code @nl_bcj_linear_stage
1 Hits, Last modified:
Power Port Pinouts @nl7_servo
1 Hits, Last modified:
Mounting example @reverso_encoder
1 Hits, Last modified:
MCSS Slide Units @slide_unit
1 Hits, Last modified: