Fulltext results:
- Safety @integrated_drive_motors
- d_drive_motors:modbus_debug]] ===== Soft landing function ===== For vertical application, it is possible to activate a function call soft landing. This function executes automatically at every switch-off (Disable command via sofwtare o... the motor falls down every time is switched off. Function can be activate using NiLAB Starter Software in M
- Pacdrive3 - Lxm62 servo drive @green_drive_motors
- typeplate file inside the flash you must use this function: {{:green_drive_motors:function.jpg?nolink&874x60|function.jpg}} It create a file inside the flash with the data of the structure ===== 4... u must delete any data inside the drive with this function block. {{:green_drive_motors:func_1.jpg?nolink&9
- Connection system @integrated_drive_motors
- ION === |**PIN** |**SIGNAL** |**DESCRIPTION** |**FUNCTION** | |1|NC|NC| | |2|CAN_H|CAN HIGH| | |3|GND|Groun... IDE === |**PIN** |**SIGNAL** |**DESCRIPTION** |**FUNCTION** | |1|RS485_B|Modbus B| | |2|RS485_A|Modbus A| |... UB 15 \\ Pinout** |**SIGNAL** |**DESCRIPTION** |**FUNCTION** | |1|RS485_B|Modbus B| | |2|RS485_A|Modbus A| |... 0.jpg}} |**PIN** |**SIGNAL** |**DESCRIPTION** |**FUNCTION** | |9|DIG_OUT_2|Digital output 2 (24V logic, PNP
- NiLAB Starter Software @nilab_starter
- Gateway values ## [2.4.1.3] - 05.3.2025 \\ - STO function added ## [2.4.1.2] - 10.2.2025 \\ - Bug fix Can ... ble window \\ - Added description for In position function in motor parameter \\ - Changed gages positions i... it is not enabled ## Bug fixes - Load and save function to use saved project load the parameter also in e... dow ## Bug fixes \\ - Correct drive reset button function ## [2.3.0.12] - 23.12.2022 ### Bug fixes - Osc
- Connection system @green_drive_motors
- == ==== Stator side with Y-TEC ==== |**PIN** |**FUNCTION** |**CONNECTOR VIEW FRONT** |**PIN** |**FUNCTION** | |12|SIN+/SLO+|{{:green_drive_motors:ytec.jpg?nolink&20... side with Speedtec M23 and M17 ==== |**PIN** |**FUNCTION** |**CONNECTOR VIEW FRONT** |**PIN** |**FUNCTION** | |12|SIN+/SLO+|{{:green_drive_motors:m23_m17.jpg?nolink
- MODBUS RTU Communication @integrated_drive_motors
- ode are : **1. Read Multiple Holding Registers - Function code 3** \\ **2. Write Single Holding Register - Function code 6** Please note that you can read a maximum... are organized in different area in respect to the function involved. |**PARAMETER AREA** |**STARTING ADDRES... nd Word - Address 4096 === Please note that with function code 6 (write register), the reply at this regist
- Glossary
- tion.\\ **Acceleration: **Change in velocity as a function of time, going from slower to faster.\\ **Accurac... otor.\\ **Deceleration**: Change in velocity as a function of time, going from faster to slower.\\ **Duty** ... ases.\\ **Velocity** \\ A change in position as a function of time (speed).\\ **Velocity** **amplifiers** \\
- Can Open Mode of Operation @integrated_drive_motors
- n|UINT32| ==== Control word bits 0x6040 - motion function ==== |**Bit position** |**Implemented Function** | |2|Quick stop| |4|Start the move| |6|Absolute or relati... s - 0x6041 ==== |**Bit position** |**Implemented Function** | |10|target reached| |12|setpoint acknowledge|
- Control Signals @integrated_pick_and_place
- atic Homing to reach the parking position.\\ This function is call Soft Landing and it is enabled by the par... y the Motor 2 Digital Output 3 set to In position function. After every Auto Homing the Motor 2 in position ... ting that the two motors complete the auto homing function waiting 3 secs or looking to the motor state usin
- Alarm Codes @nl7_servo
- lt(Switch on disabled). Method 2: Use auxiliary function “AF_ACL” Press M to select auxiliary function , Press SET to enter into “AF_ACL” , Press and hold to clear the alarm Method 3: Set IO input function as Alarm clear input “ (A-CLR)”,refer to switch i
- Safe Torque Off (STO) Port - CN6 @nl7_servo
- servo:sto_port.jpg?nolink&655x439|sto_port.jpg}} Function: Cut off motor current supply physically (through... l move under inertia and stops gradually. The STO function is set up ready to be used by factory default. Pl... ove STO connector if it is not needed. ===== STO function principle ===== STO module cuts off the motor cu
- MODBUS RTU @epulse50_dc_servodrive
- n interface. ===== Available functions ===== |**Function name** |**Function code** | |Read Holding Register|0x03| |Write Single Register|0x06| |Write Multiple Regis
- Connectors and indicators @gdi_ethercat
- } ===== LED Indicators ===== |**Indicators** |**Function** |**States** |**Color** | |CL1|Control logic|Act... D-SUB 15 Pinout** |**SIGNAL** |**DESCRIPTION** |**FUNCTION** | |1|RS485_B|Modbus B| | |2|RS485_A|Modbus A| |
- Connection system @green_drive_iso
- side with Speedtec M23 and M17 ==== |**PIN** |**FUNCTION** |**CONNECTOR VIEW FRONT** |**PIN** |**FUNCTION** | |12|SIN+/SLO+|{{:green_drive_iso:m23_m17.jpg?nolink&20
- Maintenance @green_drive_iso
- ion between the motor and the drive * Check the function of limit switch, over-travel switch where available * Check function of emergency brake or stop * Check machine mech