Fulltext results:
- CanOPEN PDO Example @mbd_servo_drive
- ====== CanOPEN PDO Example ====== The mode of operation is mapped at index 0x6060 subindex 0 with size of 1 ... 0x23 |0x00|0x1A|0x03|0x08|0x00|0x61|0x60|Mode of operation display| ==== Configuration of PDO from Master t... 0x23 |0x00|0x16|0x03|0x08|0x00|0x60|0x60|Mode of operation| ===== How to program using SDO write - Torque c... 0x23 |0x00|0x1A|0x03|0x08|0x00|0x61|0x60|Mode of operation display| ==== Configuration of PDO from Master t
- Protection
- y mains. Leakage current exceeds 3.5 mA in normal operation. \\ * Use a copper conductor with at least 10 mm²... r wrong wiring of cable connections * incorrect operation of the equipment components * wrong input of parameters before operation * malfunction of sensors, encoders and monitori... or even after an unspecified time of trouble-free operation. \\ The monitoring in the drive components will n
- uPLC @integrated_drive_motors
- the stack contains the result of the logical AND operation between itself and the y bit of the Pa parameter|... the stack contains the result of the logical AND operation between itself and the y bit of the negated Pa pa... n the stack contains the result of the logical OR operation between itself and the y bit of the Pa parameter|... n the stack contains the result of the logical OR operation between itself and the y bit of the negated Pa pa
- Safety instruction
- to the person or persons responsible for the safe operation of this equipment.\\ If the equipment is resold, ... age, assembly and installation as well as care in operation and maintenance are prerequisites for optimal and safe operation of this equipment. * Only persons who are trained and qualified for the use and operation of the equipment may work on this equipment or wi
- CanOPEN PDO @epulse50_dc_servodrive
- ====== CanOPEN PDO ====== The mode of operation is mapped at index 0x6060 subindex 0 with size of 1 byte.\\ ... ==== |**BIT Number** |**Description** |**Mode of operation** | |11|STATUSWORD_INTERNAL_LIMIT_ACTIVE| | |12|S... ==== |**BIT Number** |**Description** |**Mode of operation** | |0|CTRLWORD_BIT_SWITCH_ON| | |1|CTRLWORD_BIT_... |2|CTRLWORD_BIT_QUICK_STOP| | |3|CTRLWORD_BIT_EN_OPERATION| | |4|CTRLWORD_HOME_START|Homing| |4|CTRLWORD_ENA
- uPLC Functional description @integrated_drive_motors
- for the convenience of the user. |**AND logical operation** ||| |bit A|bit B|result| |0|0|0| |0|1|0| |1|0|0| |1|1|1| |**OR logical operation** ||| |bit A|bit B|result| |0|0|0| |0|1|1| |1|0|1... esented by the next word. After every arithmetic operation, the bit 2 of 8671 is set to 0 if the result is p... settings remain active until the next arithmetic operation is executed. A mathematical operation can be exe
- uPLC Registers @integrated_drive_motors
- ers: bit 0→timer1, bit 1→timer2 or status of last operation: bit 2→negative result, bit 3→zero result|int16| |8672|Force a double word operation: When the unit is powered on, this is 0. If it is set to 1, the first mathematical operation executed by the uPLC is done by using three doubl... word type operands. \\ After the execution of the operation 8672 is automatically set to 0. The double word r
- Motor components arrangement @ironcore_motors
- pg?nolink&600x226|single_1.jpg}} The independent operation of two or more primaries on a secondary is possib... 7|single_2.jpg}} ===== Gantry arrangement ===== Operation with two linear scales and drive controllers (gan... link&700x264|single_4.jpg}} To ensure successful operation, the axis must fulfill the following requirements... d be arranged in succession. To ensure successful operation, the primaries must be arranged in a specific gri
- Installation @mbd_servo_drive
- otes ===== \\ The MBD amplifier must be put into operation as an integrated component of a machine or equipm... cal engineering and amplifier technology (for the operation and use).| **Caution:** the misuse of the produc... .\\ Servo amplifiers may have hot surfaces during operation, it is necessary to protect the user from acciden... or disconnecting the main power switch). For this operation place the converter on an external plane from the
- Maintenance @green_drive_iso
- ns and all mechanical components and their safety operation * Check availability of all supply involved wit... e safety warranty of people involved with machine operation * Check the proper installation of the motor ... ternal influences the motor can be damaged during operation. This result in preventive maintenance of the mot
- Maintenance @green_drive_motors
- ns and all mechanical components and their safety operation * Check availability of all supply involved wit... e safety warranty of people involved with machine operation * Check the proper installation of the motor ... ternal influences the motor can be damaged during operation. This result in preventive maintenance of the mot
- Can Open Mode of Operation @integrated_drive_motors
- ====== Can Open Mode of Operation ====== The supported modes of operation are: |**Modes Of Operation \\ 0x6060** |**Description** | |1|Profile position mode| |6|Homing mode| |7|Cycl
- Can Open standard SDOs @integrated_drive_motors
- t> | <font 11pt/inherit;;black;;inherit>Disable operation option code</font> |Read and write | | <font 1... > | <font 11pt/inherit;;black;;inherit>Modes of operation</font> |Read and write | | <font 11pt/inherit;... > | <font 11pt/inherit;;black;;inherit>Modes of operation display</font> |Read only | | <font 11pt/inher
- Maintenance @integrated_drive_motors
- ns and all mechanical components and their safety operation * Check availability of all supply involved wit... e safety warranty of people involved with machine operation * Check the proper installation of the motor ... ternal influences the motor can be damaged during operation. This result in preventive maintenance of the mot
- Manufacturer responsibility
- nted or connected. The \\ same applies to cables. Operation is only permitted in the specified configurations... mbient conditions * This includes, for example, operation under water, in the case of extreme temperature f