Fulltext results:
- Connection system @integrated_drive_motors
- | |2|CAN_H|CAN HIGH| | |3|GND|Ground| | |4|+24VDC|Power| | |5|+24VDC|Power| | |6|GND|Ground| | |7|GND|Ground| | |8|CAN_H|CAN HIGH| | |9|CAN_RES|TERMINATION RESI... |2|RS485_A|Modbus A| | |3|GND|Ground| | |4|+24VDC|Power| | |5|+24VDC|Power| | |6|GND|Ground| | |7|GND|Ground| | |8|DIG_IN0|Digital Input 0 (24V logic)|Enable /
- Power Port Pinouts @nl7_servo
- ====== Power Port Pinouts ====== ===== Overview ===== {{:nl7_servo:port_3r.jpg?nolink&500x592|port_3r.j... ion port| |CN6|STO Safe Torque Off port| |X1|Main Power Supply| ===== X1 Port main power supply (230 VAC models) ===== |**Pin** |**Functions** |**Remarls** | ... t is recommended to connect a line filter to main power supply; \\ \\ It is recommended to install a fus
- Protection
- h voltage installations. \\ * Before switching on power the ground wire must be permanently connected to ... nt must be disconnected from the mains voltage or power supply. \\ * Make sure the equipment cannot be sw... s: \\ * Wait five (5) minutes after switching off power to allow capacitors to discharge before beginning... electrical connection points of a component while power is turned on. \\ * Install the covers and guards
- Wiring Diagram @nl7_servo
- le phase and three phase 220VAC. Only driver with power rating above 1500W supports three phase 220VAC. * Please use a circuit breaker for the main power supply to prevent damage to the product or machin... of the capacity when connect to a 24VDC switching power supply, especially if power supply is shared between multiple components. Insufficient supply current wi
- Pacdrive 3 - Schneider Electric @reverso_encoder
- ** (a jumper on the temperature connectors on the power port must be arranged). The Motor Data must be s... TRUE. After the sucessfully procedure, swtich the power supply of the encoder and the drive off. When the... alue without errors. Now select the PSM_Lexium62 power supply window, provide the power lines (400V) to the drive and set PowerSupplyCheckSet to 1. Go back to
- Faults Diagnosys and reset @integrated_drive_motors
- the Flash memory|Try to reset the system using a power cycle and retry| |13|0xD|SINCOS_OVERRANGE|Encoder... - Paramenter 69 (dec)| |15|0xF|MOTOR_OVERCURRENT|Power stage overcurrent|–| |16|0x10|MOTOR_DCLINK_OVERRRANGE|DC Link over range|Check the power supply level or the current capabilty of your power supply. Check the threshold level in the Parameter 4
- SIN/COS Encoder converter - Interpolator @miniature_motors
- otors:nq6_2.jpg?nolink&700x405|nq6_2.jpg}} ===== Power supply ===== ==== Using programming cable ==== When the programming calbe is used the power supply for Interpolator and the connected SIN/COS... t for the correct ioperation) or with external 5V power supply connected\\ on the power X1. {{:miniature_motors:connection_2.jpg?direct&400x415|connection_2.jp
- Electrical characteristics @motolab_actuator
- 100 A| |Rated current (max)|A|50 A| |Rated output power (max)|A|3.6 kW| |PWM Frequency|kHz|10| ===== Con... S402) * 1 RS232 with MODBUS RTU protocol ===== Power supply ===== \\ Phoenix Contact TRIO-PS-2G/3AC/24DC/40. 24 VDC output 40 Amp Power Supply 3-phase 320 -575 Vac input. {{:motolab_ac... link&200x200}} Omron S8JX-P Switch Mode DIN Rail Power Supply, 100 → 240V ac ac, dc Input, 12V dc dc Out
- Cable configuration @green_drive_iso
- ubular linear motors are provided with signal and power cable ready to be connected to different servo drives.\\ Two set of connectors are used M23 (power) and M17 (signal) speedtec and M15 (ytec) for sma... jpg?nolink&711x314|hall_signal_option.jpg}} ==== Power cable ==== {{:green_drive_motors:power_cable.jpg?nolink&311x146|power_cable.jpg}}
- Cable configuration @green_drive_motors
- ubular linear motors are provided with signal and power cable ready to be connected to different servo drive.\\ Two set of connectors are used M23 (power) and M17 (signal) speedtec and M15 (ytec) for sma... s_therm.jpg?nolink&489x330|biss_therm.jpg}} ==== Power cable (flying leads => DE20000771 for M23 connect... 5 connector on motor side) ==== {{:green_drive_motors:power_cable.jpg?nolink&311x146|power_cable.jpg}}
- Electrical connection @ironcore_motors
- e_exit.jpg?nolink&700x206|cable_exit.jpg}} ===== Power connection ===== L-series motors are normally provided with 1 m flexible shielded power cable without a connector (lead wires). Here is t... in respect to the motor and winding code. ===== Power cable with connector ===== By request, L-series ... motors can be provided with 1 m flexible shielded power cable and a male Intercontec Speedtec series conn
- Installation @mbd_servo_drive
- (by removing the fuses or disconnecting the main power switch). For this operation place the converter o... he original installation place.\\ All control and power may be live, even though the motor is not rotatin... emote control switch or remote-control switch all power supply phases of the product.\\ In the case of 3-phase power supply interrupt L1, L2 and L3; in the case of si
- Starter Status Area @nilab_starter
- w we have all the motor controls: \\ - ON - Motor power on \\ - OFF - Motor power off \\ - FAULT RESET - Reset the active fault \\ - RESET AUTOMATIC HOMING - Re... \ * 4132 - Motor Encoder Arctan [Lsb] \\ * 4631 - Power Dcbus Voltage [V] \\ * 4630 - Power i2t Value \\ * 4129 - Power i2t 1sec \\ * 7 - Motor Drive Temperatur
- Input / Output Circuits @nl7_servo
- s: DO1 and DO2 are single-ended, sharing a common power supply ground terminal; DO3+/DO3- is double-ended, having an isolated 24v power supply. {{:nl7_servo:io_2.jpg?nolink&655x716|io_2.jpg}} * Power supply is provided by user. Please be aware that reversed power supply polarity might cause damage to the driver.
- Safe Torque Off (STO) Port - CN6 @nl7_servo
- supply by blocking of PWM control signal from the power module. When the motor current is cut off, the mo... dually by blocking of PWM control signal from the power module through 2 isolated circuits. When a STO er... n be chosen. * STO is not meant to cut off the power supply of the servo drivers and motors completely. Please power off and wait for a few minutes before starting ma