meta data for this page
  •  

Search

You can find the results of your search below.

Fulltext results:

Glossary
5 Hits, Last modified:
ect the flatness of the system.\\ **Friction** \\ Resistance to motion of two surfaces that touch.\\ **Force**... proaching a position from the same direction.\\ **Resistance** \\ The opposition to the flow of charge through... he horizontal plane.\\ **Stiction** \\ Frictional resistance to initial motion.\\ **Thermal** **Resistance** \\ The equivalent thermal resistance of the motor, determined
Motor cooling @ironcore_motors
4 Hits, Last modified:
i: Current in motor cable in A\\ RU-V: Electrical resistance of the motor at 20°C in Ohm (see Chapter [[:https... echnical_data]])\\ fT: Factor temperature-related resistance raise\\ **Note: When you determine the power loss... ke the temperature-related rise of the electrical resistance into account. At a temperature rise of 105 K (from 20°C up to 125°C), for example, the electrical resistance goes up by the factor fT = 1.45.** ===== Cooling
IP69K ISO Version @green_drive_iso
3 Hits, Last modified:
H.A. process are numerous: * Highest corrosion resistance * High antibacterial capacity and anti-mould (A... static capacity * Thermal conductivity * Heat resistance * Resistance to consumption * Melting temperature: 2100 °C * Hardness: 500-600 HV * Suitable for dire
Technical data - Electrical data @lm_linear_axes
3 Hits, Last modified:
Ip|7|14| |Back EMF|V/rms/m/s|Ke|34.6|34.6| |Phase resistance|ohm|Rph|5.6|2.8| |Phase inductance|mH|Lph|31|16| ... Ip|8|17| |Back EMF|V/rms/m/s|Ke|57.5|57.5| |Phase resistance|ohm|Rph|7.6|3.8| |Phase inductance|mH|Lph|51|26| ... t|A|Ip|8.4|17| |Back EMF|V/rms/m/s|Ke|84|84| |Phase resistance|ohm|Rph|10|5| |Phase inductance|mH|Lph|74|27|
GHA Coating @miniature_motors
3 Hits, Last modified:
H.A. process are numerous: * Highest corrosion resistance * High antibacterial capacity and anti-mould (A... static capacity * Thermal conductivity * Heat resistance * Resistance to consumption * Melting temperature: 2100 °C * Hardness: 500-600 HV * Suitable for dire
Siemens Sinamics S120 / G120 @green_drive_iso
2 Hits, Last modified:
6 A| |P341|Slider weight|1.5 kg|3 Kg| |P350|phase resistance|21.5 ohm|5.03 ohm| |P356|phase inductance|35 mH|5... fter the download, enter the datasheet values for resistance and inductance, and also insert a filter on the e
Siemens Sinamics S120 / G120 @green_drive_motors
2 Hits, Last modified:
6 A| |P341|Slider weight|1.5 kg|3 Kg| |P350|phase resistance|21.5 ohm|5.03 ohm| |P356|phase inductance|35 mH|5... fter the download, enter the datasheet values for resistance and inductance, and also insert a filter on the e
Connection system @integrated_drive_motors
2 Hits, Last modified:
nd| | |8|CAN_H|CAN HIGH| | |9|CAN_RES|TERMINATION RESISTANCE| | |10|DIG_OUT_0|Digital output 0 (24V logic,PNP)... |7|CAN_H|CAN HIGH|-|Brown| |8|CAN_RES|TERMINATION RESISTANCE|-|Black| |9|CAN_H|CAN HIGH|-|Blue| In order to h
Elmo Servo Drive @miniature_motors
2 Hits, Last modified:
up of the window. The drive calculates the phase resistance and induction of the single phase.\\ The resulted values are the original Phase to Phase resistance and inductance divided by a factor of 2. {{:mini
Cables accessories @motolab_actuator
2 Hits, Last modified:
|5|CANL|Canbus L| |6|CAN_TERM_L|CAN L termination resistance 120 Ohm| |7|CAN_TERM_H|CAN H termination resistance 120 ohm| |8|DIG_IN_1|Digital Input 1 (24V logic)| |9|DIG_
Connectors @motolab_actuator
2 Hits, Last modified:
* |**Description** | |1|CANTERM|CAN L termination resistance 120 Ohm| |2|CANLOW|CAN Low| |3|CANGND|CAN Ground|... OUND|Analog ground| |9|CAN-TERM|CAN H termination resistance 120 ohm| |10|CANH|CAN High| |11|ANALOG1-IN1|Analo
Regenerative resistor @nl7_servo
2 Hits, Last modified:
generative resistor ===== |**Model** |**Internal resistance (ohm)** |**Internal resistor power rating (W)** |**Minimum resistance (ohm)** |**Minimum power rating (W)** | |NL7-EC40
Force vs. speed curve
1 Hits, Last modified:
he relevant motor-specific data, e.g. inductance, resistance and the motor constants. Varying the DC bus volta
Technical data @gdm_linear_axes
1 Hits, Last modified:
MF constant|Vrms/m/sec|Ke|32.35|42.4|43.6| |Phase resistance|ohm|Rph|10.6|7.65|5.25| |Phase inductance|mH|Lph|
Thermal Sensor @green_drive_iso
1 Hits, Last modified:
x242|ptc600_image.jpg}} Here the characteristics resistance value vs temperature detected.\\ Standard value f
Thermal Sensor @green_drive_motors
1 Hits, Last modified:
Analog control @integrated_drive_motors
1 Hits, Last modified:
Input / Output Signals @integrated_drive_motors
1 Hits, Last modified:
Installation tolerances @ironcore_motors
1 Hits, Last modified:
CANopen interface @mbd_servo_drive
1 Hits, Last modified:
MBD 230/400 Servo Drive @mbd_servo_drive
1 Hits, Last modified:
Technical data @miniature_motors
1 Hits, Last modified:
Expert Mode @nilab_starter
1 Hits, Last modified:
Electrical parameters @nl_bcj_linear_stage
1 Hits, Last modified:
Holding brake @nl7_servo
1 Hits, Last modified:
ULCO 44/66/88/132 - Belt driven linear units @ulco
1 Hits, Last modified: