Action unknown: siteexport_addpage

Connectors

epulse10_photo_azimut_1.jpg

LED Indicators

Indicator Function States Color
LED1EtherCAT Slave statusEtherCAT Ready - LED active
PreOP state - LED flashing
INIT state - LED off
SafeOP - single flash
Green
LED2EtherCAT Slave error statusEtherCAT Configuration Error - LED blinking
No Error - LED off
Unsolicited State Change - LED single flash
Application Watchdog Timeout - LED double flash
PDI Watchdog Timeout - LED active
Red
EL1EtherCAT communicationActive - connection to EtherCATOrange
EL2EtherCAT communicationBlinking - link port activityGreen
EL3EtherCAT communicationActive - connection to EtherCATOrange
EL4EtherCAT communicationBlinking - link port activityGreen

Connectors

X1 connector - 24VDC power (M12 4 poles male)

M12 power cable, female DA00022011, with flying leads.
The power cable terminates with two wires: RED (+24VDC), BLACK (GND).

da00022011_image.jpg

X2 connector - Signal and communication (M12 8 poles female)

Signal cable male DA00012011 with D-SUB 15 male connector

da0012011_image.jpg

D-SUB 15 Pinout SIGNAL DESCRIPTION FUNCTION
1RS485_BModbus B
2RS485_AModbus A
3GNDGround
4NCNot connected
5NCNot connected
6GNDGround
7GNDGround
8DIG_IN_0Digital Input 0 (24V logic)Enable/Homing
9DIG_IN_1Digital Input 1 (24V logic)Motion trigger
10DIG_OUT_0Digital output 0 (24V logic, PNP)Motor running
11DIG_OUT_1Digital output 1 (24V logic, PNP)Motor fault
12DIG_OUT_2Digital output 2 (24V logic, PNP)Programmable

The programmable outputs have the following options: In Position, Homing in progress, Overtemp fault.

X3 Motor phases and Feedback connector

pinout_miniature.jpg

ETH1 connector - EtherCAT IN (M8 4 poles female) DA0002911

da0002911_image.jpg

ETH2 connector - EtherCAT OUT (M8 4 poles female) - PATCH CABLE DA0003911

da003911_image.jpg