This page gives the performance data of the MCSS slide units. The table lists the rated and peak values for the available models.
| Parameter | MCSS080X | MCS120Q |
| Rated Force | 18,5 N | 42 N |
| Peak Force (5% duty) | 82,7 N | 187,7 N |
| Rated Current | 4.88 A | 10 A |
| Rated speed | 7 m/s | 5 m/s |
Table of stroke
| Model | Available stroke |
| MCSS080X | 10, 20, 30, 40, 50, 75 |
| MCSS120Q | 10, 20, 30, 40, 50, 75, 100 |
Notes on the data
- The rated force is the continuous force; the peak force is available for short duty cycles (5%). - The rated current is the continuous current; the rated speed is the maximum speed. - The stroke is the available travel of the slide unit. - Verify the selected model against the application requirements (duty cycle, load, speed).