Action unknown: siteexport_addpage
meta data for this page
Main technical data
Electrical parameter
| PARAMETER | UNIT | EPULSE30 | EPULSE50 | EPULSE100 |
| Rated Voltage | V | 12 - 48 | 24 - 72 - 90V (option) | 24 - 72 |
| Boost current (10 sec) | A | 50 | 120 | 200 |
| Peak current (2 minutes) | A | 40 | 100 | 150 |
| Rated current | A | 30 | 70 | 100 |
| Rated output power | kW | 1,7 | 5 | 7,9 |
| Default pwm frequency | kHz | 10 | 10 | 10 |
| Protection degree | level | IP20 | IP20 | IP20 |
| Analog Input - 0 to 10 V | qty | 2 | 2 | 2 |
| Digital Input | qty | 4 | 2 | 2 |
| Digital Ouput | qty | 2 | 2 | 2 |
| Fieldbus | type | CanOPEN | CanOPEN | CanOPEN |
| Feedback options | Hall, Sinusoidal Hall, Incremental Encoder, SinCos, Sensorless | Hall, Sinusoidal Hall, Resolver Incremental Encoder, SinCos, Sensorless, SmartABS | Hall, Sinusoidal Hall, Resolver Incremental Encoder, SinCos, Sensorless |
|
| Operating temp | degrees | 0 to 40 celsius | 0 to 40 celsius | 0 to 40 celsius |
| Connecion type | M4 busbar (DCLINK & Phases) | M5 busbar (DCLINK & Phases) | M6 busbar (DCLINK & Phases) | |
| Weight | gramms | 250 | 400 | 750 |