Slider distance for parallel drive mounting
Whne the application needs tandem parallel configuration of the integrated drive linear motor, the two or more actuator must mounted guarantee the safety distance L3 to avoid the interaction between magnetic sliders.
| MOTOR MODEL | NO INTERACTION | MEDIUM INTERACTION | STRONG INTERACTION |
| NLi080 | > 35 mm | > 15 mm to 35 mm | < 15 mm |
| NLi120 | > 65 mm | > 45 mm to 65 mm | < 45 mm |
NLi080Q Fixing points
NLi080X Fixing points
NLi120Q Fixing points
NLi120X Fixing points
NLi080Q/X slider fixing point
Slider has M4 threaded hole at each slider ends.
NLi120QX slider fixing point
Slider has M4 threaded hole at each slider ends.