meta data for this page
Safe Torque Off
This page describes the Safe Torque Off (STO) function of the Epulse10 servo drive. The STO inputs allow the safe stopping of the motor from a manual emergency button or from a safety control system.
Manual switch (Emergency button)
The illustration below shows a typical connection with a manual emergency stop button.
Safety PLC
The STO function can also be controlled by a safety system, for example a Safety PLC output or safety sensors (e.g. a safety light curtain, a safety scanner, etc.).
How STO works
- The STO inputs disable the drive output so that the motor cannot produce torque. - The function is used for the safe stopping of the machine in an emergency. - The STO can be triggered by a manual emergency stop or by a safety control system. - For the wiring and the safety parameters, refer to the connection page and the safety documentation.