meta data for this page
Fault and Warning Messages
This page lists the fault and warning messages of the MBD servo drive. When a fault occurs, the drive displays the message, opens the OK relay, and switches off the final stage — the motor produces no torque.
Any error message is displayed on the servo amplifier display. All error messages result in the opening of the OK relay contact (C5/11-12) and in the switching off of the servo amplifier final stage (motor torque). At the same time the motor-holding brake will be activated.
While the R type alarms are resettable by the user, the B type alarms are blockers. In the latter case, to reset the alarm, it must be powered off and on again the servo amplifier (24V auxiliary power and main power).
Reading the fault table
- The table lists the fault codes, the alarm type (R = resettable, B = blocking), and the cause and remedy. - Type R alarms can be acknowledged and reset by the user after the cause has been removed. - Type B alarms require a power cycle (24V auxiliary and main power) to reset. - Always remove the root cause before resetting the alarm; a repeated alarm indicates an unresolved fault.