Connection system

NLI080Q/X linear motors with CANOPEN and MODBUS RTU - DOUBLE CONNECTOR

NLi080Q/X is equipped with double connectors Hirose HR10A-10P-12S, the cable DA00002011 from motor and the PLC has the following configuration on the D-SUB 15 male connector.

cable_da00002011.jpg

CONNECTOR CLOSE TO LED POSITION

PIN SIGNAL DESCRIPTION FUNCTION
1NCNC
2CAN_HCAN HIGH
3GNDGround
4+24VDCPower
5+24VDCPower
6GNDGround
7GNDGround
8CAN_HCAN HIGH
9CAN_RESTERMINATION RESISTANCE
10DIG_OUT_0Digital output 0 (24V logic,PNP)Motor running
11DIG_OUT_1Digital output 1 (24V logic, PNP)Motor fault
12CAN_LCAN LOW

In order to have the termination on the node, please make a jumper between CAN_RES andf CAN_L (Pin 9 and Pin 11)

CONNECTOR ON THE OPPOSITE SIDE

PIN SIGNAL DESCRIPTION FUNCTION
1RS485_BModbus B
2RS485_AModbus A
3GNDGround
4+24VDCPower
5+24VDCPower
6GNDGround
7GNDGround
8DIG_IN0Digital Input 0 (24V logic)Enable / Homing
9DIG_IN1Digital Input 1 (24V logic)Motion trigger
10CAN_HCAN HIGH
11CAN_LCAN LOW
12NCNC

NLI080Q/X linear motors with MODBUS RTU only - SINGLE CONNECTOR

NLi080Q/X is equipped with single connector Hirose HR10A-10P-12S, the cable DA00002011 from motor and the PLC has the following configuration on the D-SUB 15 male connector.

cable_da00002011.jpg

D-SUB 15
Pinout
SIGNAL DESCRIPTION FUNCTION
1RS485_BModbus B
2RS485_AModbus A
3GNDGround
4+24VDCPower
5+24VDCPower
6GNDGround
7GNDGround
8DIG_IN_0Digital Input 0 (24V logic)Enable / Homing
9DIG_IN_1Digital Input 1 (24V logic)Motion trigger
10DIG_OUT_0Digital output 0 (24V logic, PNP)Motor running
11DIG_OUT_1Digital output 1 (24V logic, PNP)Motor fault
12DIG_OUT_2Digital output 2 (24V logic, PNP)Programmable

The programmable output have the following options: In Position, Homing in progress, Overtemp fault, sin/cos fault, I2T fault, Master sync, gripper command. This is programmable with NiLAB Starter software.

Pinout HIROSE Connector on motor side

conn_corrected_nli080.jpg

PIN SIGNAL DESCRIPTION FUNCTION
9DIG_OUT_2Digital output 2 (24V logic, PNP)Programmable
8GNDGround
7+24VDCPower supply
6+24VDCPower supply
5GNDGround
4DIG_IN_0Digital Input 0Enable / Homing
3DIG_IN_1Digital Input 1Motion trigger
2DIG_OUT_0Digital output 0 (24V logic PNP)Motor running
1DIG_OUT_1Digital output 1 (24V logic, PNP)Motor fault
10RS485_TXModbus
11RS485_RXModbus
12GNDGround

NLi120Q/X linear motors with MODBUS RTU only

Nli120Q/X is equipped with two M12 connectors: power female DA00022011 flying leads and signal male DA00012011.

da0012011_image.jpg

da00022011_image.jpg

The power cable terminates with two wire: RED (+24VDC), BLACK (GROUND).

The signal cable terminates with with D-SUB15 male connector with this pinout:

D-SUB 15
Pinout
SIGNAL DESCRIPTION FUNCTION
1RS485_BModbus B
2RS485_AModbus A
3GNDGround
4NCNot connected
5NCNot connected
6GNDGround
7GNDGround
8DIG_IN_0Digital Input 0 (24V logic)Enable/Homing
9DIG_IN_1Digital Input 1 (24V logic)Motion trigger
10DIG_OUT_0Digital output 0 (24V logic, PNP)Motor running
11DIG_OUT_1Digital output 1 (24V logic, PNP)Motor fault
12DIG_OUT_2Digital output 2 (24V logic, PNP)Programmable

The programmable output have the following options: In Position, Homing in progress, Overtemp fault, sin/cos fault, I2T fault, Master sync, gripper command. This is programmable with NiLAB Starter software.

NLi120Q/X linear motors with CANOPEN, MODBUS RTU and single rear connector

The hybrid for NLi120Q/X M12 and D-SUB9 connector is DA012019-5M

da012019.jpg

D-SUB9
Pinout
SIGNAL SIGNAL WIRE COLOR
1CAN_HCanbus highBrown
2CAN_LCanbus LOWGreen
3MODBUS_AModbus AYellow
4MODBUS_BModbus BGrey
5
6GNDGroundViolet
7GNDGroundBlue
824VPowerWhite
924VPowerRed

NLi120Q/X linear motors with MODBUS RTU and CANOPEN or ANALOG INPUTS

The Can cable for NLi120Q/X (third connector M12 female) and D-SUB9 connector is DA122011

can_cable.jpg

D-SUB9
Pinout
SIGNAL CAN
VERSION
ANALOG
VERSION
CAN VERSION
WIRE COLOR
1NCPULSE IN/OUT-
2CAN_LCanbus LOWDIR IN/OUTWhite
3CAN_GNDCanbus GroundGNDYellow/Green or Gray
4NC--
5NCANP (0 to 10V voltage control)-
6NCANN (4 to 20mA current control)-
7CAN_HCAN HIGH-Brown
8CAN_RESTERMINATION RESISTANCE-Black
9CAN_HCAN HIGH-Blue

In order to have the termination on the node, please make a jumper between CAN_RES andf CAN_L (Pin 8 and Pin 2)

M12 power connector on the motor side pinout

m12_power.jpg

Pin Signal Description
1+24VDC24VDC power line
2+24VDC24VDC power line
3GNDGround
4GNDGround
5NCNot connected